KATEGORIE
Zpěz k nákupu
HPE FlexNetwork 5140 48G PoE+ 4SFP+ HI Switch R9L64A RENEW
HPE FlexNetwork 5140 48G PoE+ 4SFP+ HI Switch R9L64A RENEW
59581 Kč
49241 Kč bez DPH
Dostupnost: Skladem v eshopu
Part no.: R9L64AR#ABB
Kód produktu: 115883755
Výrobce: Hewlett Packard Enterprise
Popis produktu
I/O ports and slots
48 RJ-45 autosensing 10/100/1000 PoE+ ports (IEEE 802.3 Type 10BASE-T, IEEE 802.3u Type 100BASE-TX, IEEE 802.3ab Type 1000BASE-T, IEEE 802.3at PoE+)
4 SFP+ 10GbE ports 1 port expansion module slot
Additional ports and slots
1 dual-personality (RJ-45 or mini-USB) serial console port
1 RJ-45 out-of-band management port
1 USB 2.0
Power supplies
2 power supply slots 1 minimum power supply required
Fan tray
Airflow direction is from side to back
Physical characteristics
Dimensions
17.32(w) x 18.11(d) x 1.71(h) in. (44.00 x 46.00 x 4.36 cm) (1U height)
Weight
≤9.6 kg
Memory and processor
2 GB SDRAM; Packet buffer size: 4 MB, 512 MB flash
Mounting and enclosure
Mounts in an EIA standard 19-inch telco rack or equipment cabinet (hardwareincluded)
Performance
1000 Mb Latency
< 5 µs
10 Gbps Latency
< 3 µs
Throughput
180 Mpps
Routing/Switching capacity
336 Gbps
Routing table size
8K
MAC address table size
32K
Environment
Operating temperature
23°F to 113°F (-5°C to 45°C)
Operating relative humidity
5% to 95%, noncondensing
Non-operating/Storage temperature
-40°F to 158°F (-40°C to 70°C)
Non-operating/Storage relative humidity
5% to 95%, noncondensing
Acoustic
Low-speed fan: 57.2 dB, High-speed fan: 68.9 dB; ISO 7779
Electrical characteristics
Frequency
50/60 Hz
Maximum heat dissipation
ranges from 112 BTU/hr to 5943 BTU/hr depending on power supply configuration
Voltage
100-240 VAC, rated (90-264 VAC, max)-48 to -60 VDC, rated (-36 to -72 VDC, max) (depending on power supply chosen)
Maximum power rating
1742 W (dual AC)
Idle power
40 W (dual AC)
PoE power
1440W (30W max PoE power per port)
Notes:
- Idle power is the actual power consumption of the device with no ports connected.
- Maximum power rating and maximum heat dissipation are the worst-case theoretical maximum numbers provided for planning the infrastructure with fully loaded PoE (if equipped), 100% traffic, all ports plugged in, and all modules populated
- PoE+ power range is from 360W to 1440W. PoE+ power is the power supplied by the internal power supplies. It is dependent on the type and quantity of power supplies. Device supports 1 or 2 internal modular power supplies.
Safety
UL 60950-1; EN 60825-1 Safety of Laser Products-Part 1; EN 60825-2 Safety of Laser Products-Part 2; IEC 60950-1; EN 60950-1; CAN/CSA-C22.2 No. 60950-1; FDA 21 CFR Subchapter J; RoHS Compliance; AS/NZS 60950-1; GB 4943; EAC (EurAsian Conformity Certification)
Emissions
ETSI EN300 386 V1.6.1 (2012-09); ETSI EN 300 386 V2.1.1 (2016-07); EN 55032:2015 CLASS A; CISPR 32:2015 CLASS A; AS/NZS CISPR 32:2015 CLASS A; EN 61000-3-2:2014; EN 61000-3-3:2013; FCC PART15 Subpart B CLASS A; ICES-003 Issue 7 CLASS A; ANSI C63.4-2014; VCCI-CISPR 32:2016 CLASS A
Generic
IEC 61000-4-1:2006;
IEC 61000-4-2:Ed2 2008;
IEC 61000-4-3:2020;
IEC 61000-4-3:2010;
IEC 61000-4-4:2004;
IEC 61000-4-4:2011;
IEC 61000-4-4:Ed3.0 2012;
IEC 61000-4-5:2014;
IEC 61000-4-5:2017;
IEC 61000-4-6:2013;
IEC 61000-4-6:2013 COR1:2015;
IEC 61000-4-8:2009;
IEC 61000-4-11:2004;
IEC 61000-4-11:2017;
IEC 61000-4-11:2020
ESD
Air 8KV; Con 6KV; Criteria B
Immunity
ETSI EN300 386 V1.6.1 (2012-09); ETSI EN 300 386 V2.1.1 (2016-07); EN 55035:2017; CISPR 35:2016;
Management
IMC-Intelligent Management Center; Smart MC, command-line interface; SNMP Manager
Services
Refer to the Hewlett Packard Enterprise website at: http://www.hpe.com/networking/services for details on the service-level descriptions and product numbers. For details about services and response times in your area, please contact your local Hewlett Packard Enterprise sales office.
Popis produktu
HPE FlexNetwork 5140 48G PoE+ 4SFP+ HI Switch R9L64A RENEWI/O ports and slots
48 RJ-45 autosensing 10/100/1000 PoE+ ports (IEEE 802.3 Type 10BASE-T, IEEE 802.3u Type 100BASE-TX, IEEE 802.3ab Type 1000BASE-T, IEEE 802.3at PoE+)
4 SFP+ 10GbE ports 1 port expansion module slot
Additional ports and slots
1 dual-personality (RJ-45 or mini-USB) serial console port
1 RJ-45 out-of-band management port
1 USB 2.0
Power supplies
2 power supply slots 1 minimum power supply required
Fan tray
Airflow direction is from side to back
Physical characteristics
Dimensions
17.32(w) x 18.11(d) x 1.71(h) in. (44.00 x 46.00 x 4.36 cm) (1U height)
Weight
≤9.6 kg
Memory and processor
2 GB SDRAM; Packet buffer size: 4 MB, 512 MB flash
Mounting and enclosure
Mounts in an EIA standard 19-inch telco rack or equipment cabinet (hardwareincluded)
Performance
1000 Mb Latency
< 5 µs
10 Gbps Latency
< 3 µs
Throughput
180 Mpps
Routing/Switching capacity
336 Gbps
Routing table size
8K
MAC address table size
32K
Environment
Operating temperature
23°F to 113°F (-5°C to 45°C)
Operating relative humidity
5% to 95%, noncondensing
Non-operating/Storage temperature
-40°F to 158°F (-40°C to 70°C)
Non-operating/Storage relative humidity
5% to 95%, noncondensing
Acoustic
Low-speed fan: 57.2 dB, High-speed fan: 68.9 dB; ISO 7779
Electrical characteristics
Frequency
50/60 Hz
Maximum heat dissipation
ranges from 112 BTU/hr to 5943 BTU/hr depending on power supply configuration
Voltage
100-240 VAC, rated (90-264 VAC, max)-48 to -60 VDC, rated (-36 to -72 VDC, max) (depending on power supply chosen)
Maximum power rating
1742 W (dual AC)
Idle power
40 W (dual AC)
PoE power
1440W (30W max PoE power per port)
Notes:
- Idle power is the actual power consumption of the device with no ports connected.
- Maximum power rating and maximum heat dissipation are the worst-case theoretical maximum numbers provided for planning the infrastructure with fully loaded PoE (if equipped), 100% traffic, all ports plugged in, and all modules populated
- PoE+ power range is from 360W to 1440W. PoE+ power is the power supplied by the internal power supplies. It is dependent on the type and quantity of power supplies. Device supports 1 or 2 internal modular power supplies.
Safety
UL 60950-1; EN 60825-1 Safety of Laser Products-Part 1; EN 60825-2 Safety of Laser Products-Part 2; IEC 60950-1; EN 60950-1; CAN/CSA-C22.2 No. 60950-1; FDA 21 CFR Subchapter J; RoHS Compliance; AS/NZS 60950-1; GB 4943; EAC (EurAsian Conformity Certification)
Emissions
ETSI EN300 386 V1.6.1 (2012-09); ETSI EN 300 386 V2.1.1 (2016-07); EN 55032:2015 CLASS A; CISPR 32:2015 CLASS A; AS/NZS CISPR 32:2015 CLASS A; EN 61000-3-2:2014; EN 61000-3-3:2013; FCC PART15 Subpart B CLASS A; ICES-003 Issue 7 CLASS A; ANSI C63.4-2014; VCCI-CISPR 32:2016 CLASS A
Generic
IEC 61000-4-1:2006;
IEC 61000-4-2:Ed2 2008;
IEC 61000-4-3:2020;
IEC 61000-4-3:2010;
IEC 61000-4-4:2004;
IEC 61000-4-4:2011;
IEC 61000-4-4:Ed3.0 2012;
IEC 61000-4-5:2014;
IEC 61000-4-5:2017;
IEC 61000-4-6:2013;
IEC 61000-4-6:2013 COR1:2015;
IEC 61000-4-8:2009;
IEC 61000-4-11:2004;
IEC 61000-4-11:2017;
IEC 61000-4-11:2020
ESD
Air 8KV; Con 6KV; Criteria B
Immunity
ETSI EN300 386 V1.6.1 (2012-09); ETSI EN 300 386 V2.1.1 (2016-07); EN 55035:2017; CISPR 35:2016;
Management
IMC-Intelligent Management Center; Smart MC, command-line interface; SNMP Manager
Services
Refer to the Hewlett Packard Enterprise website at: http://www.hpe.com/networking/services for details on the service-level descriptions and product numbers. For details about services and response times in your area, please contact your local Hewlett Packard Enterprise sales office.